Poor Installation of a One-Hour Fire-Resisting Wall Failure
NCQLE-2026-00035

Poor Installation of a One-Hour Fire-Resisting Wall

Poor installation practices were identified around an opening within a one-hour fire-resisting plasterboard wall. The boards have damaged and broken edges, irregular joints, narrow infill pieces, inconsistent fixing pos… Workmanship and installation Commercial Experience evidence Read lesson →
Poor Firestopping Around Hospital Service Penetrations Failure
NCQLE-2026-00034

Poor Firestopping Around Hospital Service Penetrations

Poorly executed firestopping was identified around a plastic waste pipe and copper medical-gas pipework within a hospital ceiling void. The installation appears irregular and incomplete, with visible gaps and no clear e… Workmanship and installation Healthcare Experience evidence Read lesson →
Reinforced Concrete Transformer Base Installed in the Wrong Orientation Failure
NCQLE-2026-00033

Reinforced Concrete Transformer Base Installed in the Wrong Orientation

The reinforced concrete base for the high-voltage transformer was set out and constructed in the wrong orientation. As a result, the transformer support frame and associated equipment did not achieve the required bearin… Workmanship and installation Healthcare Experience evidence Read lesson →
Structural Beams Incorrectly Connected and Misaligned Failure
NCQLE-2026-00032

Structural Beams Incorrectly Connected and Misaligned

Two structural steel beams were connected at different levels, creating an approximate 10 mm offset between their upper flanges. The connection appears to have been assembled incorrectly or fabricated without achieving … Workmanship and installation Education Experience evidence Read lesson →
Electrical Conduit Improperly Secured to Medical Gas Pipework Failure
NCQLE-2026-00031

Electrical Conduit Improperly Secured to Medical Gas Pipework

Zinc-plated electrical conduit was secured directly to copper medical gas pipes using adhesive tape instead of being independently supported. Medical gas pipework must not be used as a support for electrical services or… Workmanship and installation Healthcare Experience evidence Read lesson →
Structural Lintel Omitted Above Reduced Window Opening Failure
NCQLE-2026-00029

Structural Lintel Omitted Above Reduced Window Opening

The window openings were constructed smaller than the formed structural lintel . Instead of resolving the dimensional discrepancy through an approved redesign, additional masonry or infill was constructed above the wind… Workmanship and installation Commercial Experience evidence Read lesson →
Electrical Socket Positioned Directly Behind a Hob Failure
NCQLE-2026-00028

Electrical Socket Positioned Directly Behind a Hob

A double electrical socket and associated controls were installed immediately behind the cooking hob. Any appliance connected at this location would require its flexible lead to pass close to, or potentially across, the… Workmanship and installation Residential Experience evidence Read lesson →
Oversized Openings Around Electrical Back Boxes Failure
NCQLE-2026-00027

Oversized Openings Around Electrical Back Boxes

Circular openings were cut into the plasterboard significantly larger than the square electrical back boxes. This left unsupported gaps around the boxes that could not be properly covered or sealed by the finished acces… Workmanship and installation Residential Experience evidence Read lesson →
Non-Compliant Plug Used for Aerial Amplifier Failure
NCQLE-2026-00026

Non-Compliant Plug Used for Aerial Amplifier

An aerial amplifier within the electrical riser of a newly constructed residential block was connected to a UK socket using a non-BS 1363 plug. The two-pin plug appeared to have been inserted directly into the socket wi… Testing and commissioning Residential Experience evidence Read lesson →
Incorrect Formwork and Reinforcement Positioning Failure
NCQLE-2026-00025

Incorrect Formwork and Reinforcement Positioning

The concrete upstand or kicker was formed out of alignment with the reinforcement cage, leaving the starter bars positioned close to one edge rather than centrally within the intended concrete section. If the next concr… Workmanship and installation Commercial Experience evidence Read lesson →
Loose Structural Steelwork Fixing Near Miss
NCQLE-2026-00024

Loose Structural Steelwork Fixing

A structural bolted connection was found with the nut and washer not fully seated against the steel plate, leaving a visible gap. This indicates that the fixing may not have been correctly tightened or may have loosened… Inspection and quality control Residential Experience evidence Read lesson →
Corrosion Protection Failure to Cut Structural Bolts Failure
NCQLE-2026-00023

Corrosion Protection Failure to Cut Structural Bolts

Structural steelwork bolts were cut down with a grinder after installation, damaging or removing the protective coating from the exposed threaded ends and adjacent nuts. The untreated surfaces have subsequently corroded… Workmanship and installation Residential Experience evidence Read lesson →
Inaccessible Basin Waste Trap Concealed Within Wall Failure
NCQLE-2026-00022

Inaccessible Basin Waste Trap Concealed Within Wall

The basin waste trap was installed within the wall construction without a suitable access panel or other means of safely inspecting, cleaning or servicing it. Any future maintenance or blockage removal would require the… Workmanship and installation Healthcare Experience evidence Read lesson →
Cable Tray Resting on Copper Medical-Gas Pipework Failure
NCQLE-2026-00020

Cable Tray Resting on Copper Medical-Gas Pipework

Zinc-plated electrical cable trays were installed in direct contact with and supported by copper medical-gas pipes. Medical-gas pipework must not be used to support electrical containment, and each service should have i… Workmanship and installation Healthcare Experience evidence Read lesson →
Incorrect Back Box Installed in a 60-Minute Fire-Resisting Wall Failure
NCQLE-2026-00019

Incorrect Back Box Installed in a 60-Minute Fire-Resisting Wall

An incorrectly sized plastic electrical back box was installed within a 60-minute fire-resisting plasterboard wall instead of the specified metal back box. To make the retaining lugs engage, the installer broke away and… Products and materials Commercial Experience evidence Read lesson →
Plastic Packers Used in Structural Lift-Shaft Steelwork Failure
NCQLE-2026-00018

Plastic Packers Used in Structural Lift-Shaft Steelwork

Plastic packers were found between structural steel components within the lift shaft, where steel finger packers or engineered metal shims should have been used. Unless specifically designed and approved for the applica… Products and materials Healthcare Experience evidence Read lesson →
Gas Supply Pipe Installed Without a Protective Sleeve Failure
NCQLE-2026-00017

Gas Supply Pipe Installed Without a Protective Sleeve

The gas supply pipe to a newly built house appeared to pass directly through the external cavity wall without a suitable continuous sleeve. Mortar had also been applied directly around and onto the copper pipe. This ins… Workmanship and installation Residential Experience evidence Read lesson →
Incorrectly Sized and Inadequately Fixed Fire Doorset Failure
NCQLE-2026-00016

Incorrectly Sized and Inadequately Fixed Fire Doorset

The fire doorset appeared to be undersized for the structural opening, resulting in an excessive gap between the frame and the supporting wall. The gap had been built out using multiple layers of plasterboard and intume… Workmanship and installation Healthcare Experience evidence Read lesson →
Incorrect Installation of an Open-State Cavity Barrier Failure
NCQLE-2026-00015

Incorrect Installation of an Open-State Cavity Barrier

The intumescent open-state cavity barrier was installed too far forward and finished flush with the vertical cavity barrier. Once the façade panels were installed, the barrier would press tightly against the rear of the… Workmanship and installation Residential Experience evidence Read lesson →
Glazing Panels Installed in the Wrong Orientation Improvement
NCQLE-2026-00014

Glazed panels installed wrong way round

During inspection of the completed façade, several glazed panels appeared to have been installed the wrong way round. This was evident from the significant variation in colour and reflectivity, with some panels displayi… Workmanship and installation Commercial Experience evidence Read lesson →
Premature Corrosion of Powder-Coated Rainscreen Panels Failure
NCQLE-2026-00013

Premature Corrosion of Powder-Coated Rainscreen Panels

Significant areas of corrosion were identified on aluminium rainscreen panels only eight years after installation. Investigation indicated that the powder-coating thickness was below the specified requirement, resulting… Products and materials Residential Experience evidence Read lesson →
Porous architectural wall panels were observed with extensive vertical streaking Failure
NCQLE-2026-00012

Porus Panels install on UK rail infrastructure project

During the inspection of porous architectural wall panels installed on a major UK rail infrastructure project, significant vertical staining, water marks and colour variations were observed across the completed finish, … Products and materials Rail and transport Experience evidence Read lesson →
Incorrect Framework install Failure
NCQLE-2026-00009

Incorrect Materials installed in Facade Framework

The façade support framework had been assembled using small aluminium angles and flat aluminium strips instead of the specified structural T-sections required to support stone panels weighing approximately 100 kg each. … Workmanship and installation Commercial Experience evidence Read lesson →
Incorrect Install of Intumescent open state fire barrier Failure
NCQLE-2026-00008

Incorrect Install of Intumescent open state fire barrier

A short section of the open-state intumescent cavity barrier appears to have been friction-fitted between a continuation of the barrier, with no visible mechanical fixing. The installation may therefore rely on the plas… Workmanship and installation Residential Experience evidence Read lesson →
Badly Installed brick Arch Failure
NCQLE-2026-00006

The brick arch appears structurally unsafe.

The brick arch appears structurally unsafe. Perforated bricks have been laid in an unsuitable orientation, mortar joints are irregular and incompletely filled, and the crown lacks a properly formed and bonded keystone a… Workmanship and installation Commercial Documented evidence Read lesson →
Incorrect Bricklaying on a window Arch Failure
NCQLE-2026-00005

The brickwork demonstrates poor workmanship

The brickwork demonstrates poor workmanship, including irregular and incomplete bed and perpend joints, excessive mortar voids and inadequate bedding around the wall ties. The ties appear to have been installed in the w… Workmanship and installation Commercial Documented evidence Read lesson →
Covering up the Fire Barrier face with foil Tape Failure
NCQLE-2026-00004

Covering up the Fire cavity Barrier face with foil Tape

The cavity barrier face has been covered with foil tape, apparently masking an inadequate fit rather than correcting it. Foil tape cannot replace the required physical contact and compression between a closed-state cavi… Workmanship and installation Residential Documented evidence Read lesson →
Corroded Fire Cavity Hanger after 8 years Failure
NCQLE-2026-00003

Fire Cavity Barrier hanger failure after 8 years

The cavity-barrier support hanger has suffered severe premature corrosion after approximately eight years, with extensive rusting, delamination and apparent loss of metal section around the fixing and along the support.… Products and materials Residential Multi Project evidence Read lesson →
Combustible materials covered with EPDM Failure
NCQLE-2026-00001

Encapsulation of Combustibles using EPDM membrane

It was found that the Facade contractor was using EPDM membrane to encapsulate Combustible materials around windows on a HRB over 18M. No update from Fire engineer and no valid fire engineer report available Clien… Products and materials Residential Experience evidence Read lesson →
Incorrect Junction Between Open-State and Vertical Fire Barriers Failure
NCQLE-2026-00030

Incorrect Junction Between Open-State and Vertical Fire Barriers

The corner junctions between the horizontal open-state cavity barrier and the vertical fire barriers around the window were installed incorrectly and did not follow the manufacturer’s approved design. The barriers were … Workmanship and installation Residential Experience evidence Read lesson →
Structural bracket made up on site with poor welding Failure
NCQLE-2026-00011

Structural bracket made up on site with poor welding

A support bracket for a glass balustrade installed more than 18 metres above ground level appeared to have been fabricated or modified on site and did not match the approved design. The welded connection showed poor wor… Workmanship and installation Residential Experience evidence Read lesson →
Severe undercut on Structural Steel Bracket Failure
NCQLE-2026-00010

Severe undercut on Structural Steel BMU Bracket

Severe undercut was observed along the toe of a fillet weld connecting a structural steel bracket. The undercut reduces the effective thickness of the parent material and creates a stress concentration that may initiate… Workmanship and installation Residential Experience evidence Read lesson →
Incorrect placement of Intumescent Fire batt Failure
NCQLE-2026-00007

Incorrect placement of Intumescent Fire batt and Bracket

The open-state cavity barrier appears to be incorrectly positioned against the façade C-channel rather than installed in accordance with the approved supporting-substrate detail. The façade carrier bracket obstructs the… Workmanship and installation Residential Experience evidence Read lesson →
Incorrect EPDM install Failure
NCQLE-2026-00002

Incorrect Install of EPDM around window Openings

The EPDM around the window opening is poorly formed and inadequately bonded, with loose folds, creasing, irregular joints, exposed insulation and apparent gaps at critical interfaces. The installation does not demonstra… Workmanship and installation Residential Experience evidence Read lesson →